One on hand equals two on the job!
DFX-8 Flaw Detector & Thickness Gauge
Flaw Detector Features
Pulser Voltage: 100 – 200 volt square wave.
Gain: 0- 110 dB range.
Filters: Wide, 1, 2, 5 & 10 MHz
Sizing Toolkits: DAC, AWS, TCG, DGS.
Blanview sunlight viewable QVGA display (320×240 pixels).
P.R.F. – 8Hz to 2kHz, adjustable.
Screen Refresh Rate: 60 Hz.
Detection Modes: Z-Cross, Flank & Peak.
Thickness Gauge Features
Auto: probe zero, probe recognition, and temperature compensation.
Transducer Types: Dual element, Single Contact & Delay line.
Measurement Modes: Includes pulse-echo (P-E), echo-echo (E-E), echo-echo verify (E-EV), pulse-echo coating (PECT), pulse-echo temperature compensation (PETP) & coating only (CT) modes to address a variety of applications.
Three independent gates.
Large data storage with multiple formats: Alpha numeric grid and sequential w/auto identifiers.
Store up to 64 custom setups.
General Specifications
Size: 8.5W x 6.5H x 2.5D in (216 x 165 x 70mm).
Weight: 4.5 lbs (2.04 kgs), with batteries.
Case: Extruded aluminum body with nickel plated aluminum end caps (gasket sealed).
Display: Blanview sunlight readable QVGA TFT color display (320 x 240 pixels). Viewable area 4.54 x 3.40 in (115.2 x 86.4 mm), or 5.7 in (144.78 mm) diagonal. 16 color palette, multiple color options and variable
brightness.
Screen Refresh Rate: 60Hz.
Display Views: Flaw Detector: Full wave, +/- Rectified, or RF. Thickness Gauge: Digits, +/- Rectified, RF, or B-Scan.
Timing: Precision TCXO timing with single shot 100 MHz 8 bit ultra low power digitizer.
Measurement Gates: Two independent gates (Flaw), and three gates (thickness). Start & width adjustable over full range. Amplitude 5-95%, 1% steps. Positive or negative triggering for each gate with audible and visual alarms.
Operating Temperature: 14 to 140F (-10C to 60C).
Environmental: Meets IP65 requirements
Certification
Thickness Gauge: Factory calibration traceable to NIST & MIL-STD-45662A.
Flaw Detector: EN12668-1 compliant.