E-58D is a Method D (hydrophilic) inspection penetrant emulsifier approved to AMS-2644 for use with FP-94, FP-93A(M), FP-95A(M), and FP-97A(M) fluorescent (Type 1) post emulsifiable penetrants. Method D emulsifiers are used either by immersion or spray on. The emulsifier is diluted with water to the desired working concentration. For
immersion the use range is 17 – 20 % or 1 part emulsifier to 4 parts water. The concentration is controlled by using a brix refractometer and a concentration chart. For spray applications the concentration is kept below 5 %. In immersion applications the penetrant covered part is given a quick water wash and then immersed into the gently agitated
emulsifier from 30 seconds to 2 minutes depending upon the part surface roughness. The part is removed and washed. The pre-rinse step may be omitted for the spray application method of the emulsifier.
E-58D is listed on the Qualified Products List for AMS-2644E. It meets the requirements of AMS-2647,ASME Boiler and Pressure Vessel Code, ASTM E-165, and ASTM E-1417, for penetrant inspection materials.
Specifications
AMS -2644 AMS-2647
ASME B & PV code Sec. V
ASTM E-165 ASTM E-1417
ISO 3452-2:2005
P & W PMC # 4355-7 & -47
RR RPS-702-7, CSS-232, Omat # 621B
Typical Physical Properties
Form: clear reddish orange viscous liquid
Density:1.08 K/L
Flash Point: > 93¢ªC (> 200¢ªF)
Viscosity 20.3 mm2/s
Water content: 3.7%
Water tolerance: > 5%
Corrosion of aluminum: none
Corrosion of carbon steel: none
Corrosion of magnesium: none
Corrosion of stainless steel: none
Corrosion of titanium: none
Chloride content: < 100 ppm (0.01%)
Fluoride content: < 50 ppm (0.005%)
Sulfur content: < 100 ppm (0.01%)
Mercury: none
VOC¡¯s: 0 g/L
Ozone layer depleting substances: none
PCB¡¯s: none